KL-P004 Air Mattress — Tubular Alternating Pressure Mattress for Hospital Beds

Quick answer. The Keling KL-P004 is a hospital bed air mattress with tubular air-cell construction and a size of 190 × 90 cm, supplied with an electric pump featuring a digital control panel. It is manufactured by Keling Medical (Jiangsu Keling Medical Appliances Co., Ltd.) for pressure-relief and anti-decubitus use across a variety of hospital scenarios.
Mattress size (L × W)
190 × 90 cm
Construction
Tubular air-cell
Application
Applicable to a variety of hospital scenarios
Markdown
ISO 13485:2016 CE (EU MDR) Global export OEM available

Overview

The KL-P004 air mattress is a tubular alternating pressure mattress that provides a step up in pressure-redistribution capability from bubble-cell designs. Where the KL-P003 uses small rounded bubble cells, the KL-P004 uses larger tubular (cylindrical) air channels arranged across the mattress surface. The greater air volume per cell translates to deeper pressure relief under the patient's body contours, making the KL-P004 more appropriate for higher-risk patients or longer-duration immobility situations.

The electric pump supplied with the KL-P004 includes a digital controller, allowing nursing staff or clinicians to set and monitor the inflation pressure precisely and adjust it for the patient's body weight and risk assessment. Digital control improves consistency of therapeutic pressure delivery compared to analogue dial systems and makes it simpler to verify and document the mattress pressure setting as part of pressure injury prevention protocols.

The tubular cell pattern visible on the mattress surface — with both horizontal tube rows and connector ridges — is the established format for alternating pressure systems in clinical use. The KL-P004 deploys this technology in a 190 × 90 cm format that mounts over existing standard hospital beds, bringing advanced pressure management to ward environments without requiring dedicated air-loss bed frames or replacement bed investment.

Quick facts

  • The Keling KL-P004 is a tubular air-cell hospital bed mattress for alternating pressure and anti-decubitus applications.
  • The mattress measures 190 × 90 cm, compatible with standard hospital bed frames.
  • The KL-P004 is supplied with an electric pump featuring a digital controller for pressure setting and adjustment.
  • The tubular cell construction differs from the bubble-cell design of the KL-P003, providing larger-diameter air channels for deeper pressure redistribution.
  • Applicable to a variety of hospital scenarios requiring dynamic pressure relief.
  • The KL-P004 is produced by Keling Medical, a Chinese medical equipment manufacturer with more than 20 years of industry experience.

Key features

  • Tubular air-cell construction

    large-diameter cylindrical air channels provide deeper body-contour pressure redistribution than bubble-cell designs, suited to higher-risk patients.

  • Digital pump with controller

    electric pump unit includes a digital control panel for precise pressure setting, monitoring and adjustment based on patient weight and risk.

  • Alternating pressure function

    cells inflate and deflate in alternating cycles to prevent sustained pressure on any skin area, reducing pressure injury risk for immobile patients.

  • Standard 190 × 90 cm footprint

    fits directly onto standard hospital bed frames without requiring bed replacement.

  • Wide clinical applicability

    described as applicable to a variety of hospital scenarios from general wards to high-dependency environments.

  • Complete kit

    supplied as a mattress-and-pump system, ready for clinical deployment.

Technical specifications

Specifications are subject to change; dimensional tolerances may apply. Contact Keling Medical for the latest datasheet.

6 parameters for KL-P004

KL-P004 technical specifications
ModelKL-P004
Product typeAir mattress (tubular cell, alternating pressure)
Mattress size (L × W)190 × 90 cm
InflationElectric pump with digital controller (supplied)
ConstructionTubular air-cell
ApplicationApplicable to a variety of hospital scenarios

Applications

The KL-P004 tubular air mattress is deployed in general wards, ICUs, surgical recovery areas, geriatric and rehabilitation wards, and long-term care facilities for patients at moderate to high risk of pressure injury development. It is placed on standard hospital beds as a pressure-redistributing overlay surface, and its digital pump facilitates integration into pressure injury prevention care pathways.

Questions buyers ask

What is the Keling KL-P004 air mattress used for?

The KL-P004 is a tubular alternating pressure mattress for hospital beds used in the prevention and management of pressure injuries in immobile or low-mobility patients. The alternating air-cell inflation cycle continuously changes the pressure distribution across the mattress surface to prevent sustained skin ischemia.

How does the KL-P004 differ from the KL-P003 air mattress?

Both are air mattresses for pressure relief, but the KL-P004 uses a tubular (cylindrical) air-cell design with a digital pump controller, while the KL-P003 uses a bubble-cell design. The tubular cells of the KL-P004 provide a larger air volume per cell for deeper pressure redistribution, and the digital controller allows more precise pressure management — making the KL-P004 suited to higher-risk patients or clinical protocols requiring documented pressure settings.

What does the KL-P004 pump include?

The supplied electric pump unit for the KL-P004 includes a digital control panel for setting and monitoring mattress inflation pressure. This allows clinical staff to configure and record the therapeutic pressure setting for individual patients and adjust it as the patient's condition changes.

Is the KL-P004 available for hospital project procurement?

Yes. Keling Medical supplies air mattresses and clinical bed accessories to hospitals and distributors worldwide through its Shanghai export center. Contact Keling Medical at https://www.kelingmed.com for project pricing, unit quantities and export documentation.

Get a quote for KL-P004

Tell us the quantity, voltage and delivery port. The export team in Shanghai replies by email with pricing, lead time and the full datasheet.

Or email inquiry@shkeling.com

Type at least two characters. Use ↑ ↓ to move and Enter to open.

Products SolutionsCompanyInsightsContact