Hospital Beds · KL-BC103-A

KL-BC103-A Electric Hospital Bed | 5-Function Bed Alternative Style

The Keling KL-BC103-A is a 5-function electric hospital bed sharing the same functional specification as the KL-BC103 — backrest to 70±10°, knee-rest to 30±10°, height 450–760 mm, Trendelenburg/reverse Trendelenburg 12±5°, 240 kg safe working load — in an alternative visual design. External dimensions are 2150 × 960 × (450–760) mm; bed surface is 1925 × 900 mm. Manufactured by Keling Medical (Keling Medical).

Model
KL-BC103-A
Category
Hospital Beds
Supplier
Keling Medical
Order type
B2B, distributor and project inquiry
  • The Keling KL-BC103-A is a 5-function electric hospital bed offering an alternative aesthetic design to the KL-BC103.
  • Backrest adjusts electrically to 70±10° and knee-rest independently to 30±10°.
  • Electric height adjustment spans 450–760 mm, providing a 310 mm travel range.
  • Trendelenburg and reverse Trendelenburg each reach 12±5° for full postural tilt capability.
CertificatesConfirm by model
MOQConfirm by quote
Lead timeConfirm by order
CustomizationFeasibility review

Include quantity, destination, voltage, accessories, required certificates and delivery target.

# KL-BC103-A Electric Hospital Bed — 5-Function Bed in Alternative Design Style

Quick answer: The Keling KL-BC103-A is a 5-function electric hospital bed sharing the same functional specification as the KL-BC103 — backrest to 70±10°, knee-rest to 30±10°, height 450–760 mm, Trendelenburg/reverse Trendelenburg 12±5°, 240 kg safe working load — in an alternative visual design. External dimensions are 2150 × 960 × (450–760) mm; bed surface is 1925 × 900 mm. Manufactured by Keling Medical (Keling Medical).

Quick Facts

  • The Keling KL-BC103-A is a 5-function electric hospital bed offering an alternative aesthetic design to the KL-BC103.
  • Backrest adjusts electrically to 70±10° and knee-rest independently to 30±10°.
  • Electric height adjustment spans 450–760 mm, providing a 310 mm travel range.
  • Trendelenburg and reverse Trendelenburg each reach 12±5° for full postural tilt capability.
  • Safe working load is 240 kg; bed surface size is 1925 × 900 mm.
  • External dimensions are 2150 × 960 × (450–760) mm with a ±20 mm dimensional tolerance.

Overview

The KL-BC103-A electric hospital bed delivers the same clinical performance as the KL-BC103 in a distinct visual design style, giving hospitals and procurement teams the flexibility to select a bed that aligns with ward aesthetics or institutional branding preferences while maintaining identical technical specifications. All five electrically controlled functions — backrest, knee-rest, height, Trendelenburg and reverse Trendelenburg — are powered independently, enabling precise patient positioning throughout inpatient care.

The 70±10° backrest range supports respiratory positioning, enteral feeding protocols and comfortable semi-recumbent patient rest. The independent 30±10° knee-rest limits patient sliding toward the foot of the bed — a common concern when the backrest is elevated — and reduces lumbar and sacral pressure that can contribute to pressure injury development in long-stay patients.

Height adjustment from 450 mm enables low-entry transfers that reduce fall risk, while the 760 mm upper limit brings the patient surface to a nursing-task height that reduces staff back strain. The 240 kg load rating ensures the KL-BC103-A accommodates patients across a wide body weight range without compromising structural safety.

Key Features

  • Alternative design style — same 5-function specification as KL-BC103 in a distinct visual design for ward aesthetic flexibility.
  • 5-Function electric actuation — independent motorized control of backrest, knee-rest, height, Trendelenburg and reverse Trendelenburg.
  • Backrest to 70±10° — broad electric adjustment range for respiratory care, feeding and therapeutic positions.
  • Knee-rest to 30±10° — independent elevation limits patient sliding and supports post-operative lower limb care.
  • Height range 450–760 mm — full electric height travel for patient safety and nursing ergonomics.
  • Trendelenburg / reverse Trendelenburg 12±5° — bidirectional postural tilt for drainage, circulatory and surgical positioning.
  • 240 kg safe working load — rated capacity for a broad inpatient population.
  • Compact 960 mm external width — space-efficient footprint for standard ward bays.

Technical Specifications

ParameterValue
ModelKL-BC103-A
Product typeElectric hospital bed (5-function)
Backrest adjustment70±10°
Knee-rest adjustment30±10°
Height adjustment450–760 mm
Reverse Trendelenburg12±5°
Trendelenburg12±5°
Safe working load240 kg
External size (L × W × H)2150 × 960 × (450–760) mm
Bed surface size (L × W)1925 × 900 mm
Dimensional tolerance±20 mm

Specifications are subject to change; dimensional tolerances may apply. Contact Keling Medical for the latest datasheet.

Applications

The KL-BC103-A is suitable for general medical and surgical wards, post-operative recovery rooms, elderly care units and long-term inpatient facilities. Its design-style differentiation from the KL-BC103 makes it a useful choice when mixed bed procurement requires visual distinction between functional zones or ward types.

Product questions

Frequently Asked Questions

Answers for initial model evaluation. Commercial terms, certificates and final configuration remain subject to written confirmation.

What is the Keling KL-BC103-A electric hospital bed used for?

The KL-BC103-A is a 5-function electric hospital bed for general ward and inpatient clinical settings. It provides electric control of backrest, knee-rest, height, Trendelenburg and reverse Trendelenburg tilt, supporting standard nursing care, post-operative recovery and pressure-injury prevention protocols.

How does the KL-BC103-A differ from the KL-BC103?

The KL-BC103-A and KL-BC103 share identical technical parameters — same 5-function specification, 240 kg load, 450–760 mm height range, 12±5° Trendelenburg angles and 2150 × 960 mm external dimensions. The difference is in the visual design style of the bed frame and panels, allowing facilities to select an aesthetic that suits their ward environment.

What are the bed surface and external dimensions of the KL-BC103-A?

The KL-BC103-A has a bed surface of 1925 × 900 mm and an external size of 2150 × 960 × (450–760) mm. The 960 mm external width is suited to standard ward bays while providing a 900 mm usable patient surface.

Can the KL-BC103-A be sourced in bulk for hospital projects?

Yes. Keling Medical supports wholesale, project-volume and OEM orders for hospital procurement projects through its Shanghai sales and export center. Visit https://www.kelingmed.com to contact the export team for quotations and product configuration options.

B2B procurement information

Items to confirm for KL-BC103-A

A product page supports initial selection. The following commercial and compliance details must be confirmed for the actual destination and order.

Product configuration

Functions, dimensions, accessories, voltage, plug, language, color and optional components.

Compliance documents

Current certificate scope, declaration, datasheet and destination-market document needs.

Commercial terms

Unit price, MOQ, lead time, Incoterm, payment, warranty and spare-parts arrangement.

Packing information

Package type, quantity per package, dimensions, gross weight and shipping marks.

Project coordination

Equipment schedule, model alternatives, required delivery milestone and document submission plan.

Order confirmation

Final specifications and documents should be attached to the formal quotation or contract.

Important: Website specifications may be updated. Use the latest signed quotation, datasheet and approved configuration as the purchasing reference.

Model-specific RFQ

Request a commercial and document review

To reduce back-and-forth, include the following information:

  • Model: KL-BC103-A
  • Required quantity and purchasing frequency
  • Destination country and preferred Incoterm
  • Voltage, plug, language and accessories
  • Required certificates or tender documents
  • Target delivery date and packaging marks

Do not send patient information or other sensitive medical data.

Send your requirements

If no external form service is configured, your email application will open with the inquiry details. Do not submit patient data or sensitive personal information.

B2B project inquiry

Planning a medical equipment project?

Share your BOQ, quantities, destination, delivery target and required documents.