Operating Tables · KL-D-III

KL-D-III Electric Operating Table | Multi-Position Electro-Hydraulic Surgical Table

The Keling KL-D-III is an electric operating table with CPU-controlled electro-hydraulic working principle, height adjustment from 700–1000 mm (± 50 mm), lateral tilt ≥ 20°/≥ 20°, Trendelenburg ≥ 20°/≥ 15°, and a radiolucent carbon plastic tabletop. It is manufactured by Keling Medical (Keling Medical) for hospitals and medical distributors.

Model
KL-D-III
Category
Operating Tables
Supplier
Keling Medical
Order type
B2B, distributor and project inquiry
  • The Keling KL-D-III is an electric operating table suitable for various operations conducted by medical facilities.
  • Height adjustment range is 700 to 1000 mm (± 50 mm) with electro-hydraulic drive.
  • Lateral tilt reaches ≥ 20° on each side; Trendelenburg/reverse-Trendelenburg is ≥ 20°/≥ 15°.
  • The tabletop is made of imported carbon plastic plate, offering radiolucency for C-arm and X-ray imaging.
CertificatesConfirm by model
MOQConfirm by quote
Lead timeConfirm by order
CustomizationFeasibility review

Include quantity, destination, voltage, accessories, required certificates and delivery target.

# KL-D-III Electric Operating Table — CPU-Controlled Electro-Hydraulic Table for Multi-Specialty Surgery

Quick answer: The Keling KL-D-III is an electric operating table with CPU-controlled electro-hydraulic working principle, height adjustment from 700–1000 mm (± 50 mm), lateral tilt ≥ 20°/≥ 20°, Trendelenburg ≥ 20°/≥ 15°, and a radiolucent carbon plastic tabletop. It is manufactured by Keling Medical (Keling Medical) for hospitals and medical distributors.

Quick Facts

  • The Keling KL-D-III is an electric operating table suitable for various operations conducted by medical facilities.
  • Height adjustment range is 700 to 1000 mm (± 50 mm) with electro-hydraulic drive.
  • Lateral tilt reaches ≥ 20° on each side; Trendelenburg/reverse-Trendelenburg is ≥ 20°/≥ 15°.
  • The tabletop is made of imported carbon plastic plate, offering radiolucency for C-arm and X-ray imaging.
  • Actions are controlled by an electro-hydraulic working principle and remote controller with CPU; one-key reset function is supported.
  • The table is formed with alloy aluminium by forging process, and the column and base cover are 304 stainless steel.

Overview

The KL-D-III electric operating table brings CPU-based electro-hydraulic control to a broad range of surgical disciplines. Both AC and DC power modes are supported — with a one-key reset function — so the table maintains full operability in any power situation while case-to-case reset is accomplished at the press of a single button. Positions are commanded through a handheld remote controller and direct panel; both work on the same CPU platform, ensuring consistent and accurate movement across all axes.

The table surface is constructed from imported carbon plastic plate, delivering radiolucency for intraoperative fluoroscopy through the full length of the table. The alloy aluminium forged frame and 304 stainless steel column and base cover combine lightweight construction with the structural rigidity needed to support patient loads across the extended height and tilt ranges. Removable side rails are also 304 stainless steel, keeping all surfaces corrosion-resistant and straightforward to wipe down.

The polyurethane mattress is once-foam-moulded without seams, using imported artificial leather with high-density memory foam. This construction prevents fluid ingress between the mattress and upholstery during fluid-intensive procedures, accelerating terminal cleaning. The foot-operated brake device locks and unlocks the table securely during OR repositioning.

Key Features

  • CPU electro-hydraulic control — processor-managed hydraulic actuation provides precise, repeatable movement across all table axes via remote controller.
  • AC/DC dual-purpose power with one-key reset — maintains function during power interruption; single-button return to horizontal position streamlines case turnover.
  • Radiolucent carbon plastic tabletop — imported carbon plate provides clear X-ray and C-arm imaging without repositioning the patient.
  • Alloy aluminium forged frame — lightweight, high-strength aluminium forged structure with 304 stainless steel column and base cover.
  • One-piece polyurethane mattress — seamless foam construction from imported artificial leather and high-density memory foam; antibacterial and easy to disinfect.
  • Foot-operated brake device — conveniently locks and unlocks the table for safe OR repositioning.
  • Detachable head and leg plates — split, interchangeable head board and leg plates allow unobstructed C-arm access from either end.

Technical Specifications

ParameterValue
ModelKL-D-III
Product typeElectric operating table
Length2000 ± 100 mm
Width520 ± 20 mm
Height Adjustment(700–1000) ± 50 mm
Tilt Left / Tilt Right≥ 20° / ≥ 20°
Trendelenburg / Rev-Trend≥ 20° / ≥ 15°
Headboard Upwards≥ 45°
Headboard Downwards≥ 90°
Backboard Upwards≥ 70°
Backboard Downwards≥ 20°
Waist board lifting100 ± 20 mm
Leg plate upwards≥ 10°
Leg plate downwards≥ 90°
Leg plate abduction≥ 180°
Lumbar lordosis angle "∧"≤ 160°
Lumbar kyphosis angle "∨"≤ 105°
Input power VA400 ± 10%
Power Supply AC220V ± 22V 50Hz ± 1Hz

Specifications are subject to change; dimensional tolerances may apply. Contact Keling Medical for the latest datasheet.

Applications

The KL-D-III electric operating table is deployed in general surgery, abdominal and thoracic surgery, orthopaedics, urology, gynaecology and neurological procedures. Its wide tilt range (≥ 20° each side) and full leg plate abduction (≥ 180°) support both lithotomy and kidney-bridge positions, making it a versatile choice for mixed-case surgical suites.

Product questions

Frequently Asked Questions

Answers for initial model evaluation. Commercial terms, certificates and final configuration remain subject to written confirmation.

What is the Keling KL-D-III electric operating table used for?

The KL-D-III is a multi-purpose electric operating table designed for various surgical procedures in hospitals and medical facilities. Its CPU-controlled electro-hydraulic system, carbon tabletop, and comprehensive range of positions make it suitable for general, abdominal, orthopaedic, urological and gynaecological operations.

What positioning range does the KL-D-III offer?

The KL-D-III supports lateral tilt ≥ 20° on each side, Trendelenburg ≥ 20°/reverse-Trendelenburg ≥ 15°, headboard upward ≥ 45° and downward ≥ 90°, backboard upward ≥ 70°/downward ≥ 20°, leg plate upward ≥ 10°/downward ≥ 90°, leg plate abduction ≥ 180°, waist board lifting 100 ± 20 mm, and lumbar bridge adjustment.

How does the CPU control system work on the KL-D-III?

The KL-D-III uses a CPU-based electro-hydraulic system that processes commands from the handheld remote controller and the built-in panel controller. Both operate on the same processor platform, providing consistent, accurate positioning. The one-key reset function returns the table to a neutral horizontal position with a single button press.

Is the KL-D-III available for export or wholesale purchase?

Yes. Keling Medical supplies hospitals and distributors worldwide through its Shanghai sales and export center. Wholesale and project inquiries, as well as OEM options, are available at https://www.kelingmed.com.

B2B procurement information

Items to confirm for KL-D-III

A product page supports initial selection. The following commercial and compliance details must be confirmed for the actual destination and order.

Product configuration

Functions, dimensions, accessories, voltage, plug, language, color and optional components.

Compliance documents

Current certificate scope, declaration, datasheet and destination-market document needs.

Commercial terms

Unit price, MOQ, lead time, Incoterm, payment, warranty and spare-parts arrangement.

Packing information

Package type, quantity per package, dimensions, gross weight and shipping marks.

Project coordination

Equipment schedule, model alternatives, required delivery milestone and document submission plan.

Order confirmation

Final specifications and documents should be attached to the formal quotation or contract.

Important: Website specifications may be updated. Use the latest signed quotation, datasheet and approved configuration as the purchasing reference.

Model-specific RFQ

Request a commercial and document review

To reduce back-and-forth, include the following information:

  • Model: KL-D-III
  • Required quantity and purchasing frequency
  • Destination country and preferred Incoterm
  • Voltage, plug, language and accessories
  • Required certificates or tender documents
  • Target delivery date and packaging marks

Do not send patient information or other sensitive medical data.

Send your requirements

If no external form service is configured, your email application will open with the inquiry details. Do not submit patient data or sensitive personal information.

B2B project inquiry

Planning a medical equipment project?

Share your BOQ, quantities, destination, delivery target and required documents.

Discuss Your Requirements →