The Keling KL-BC107 is a 2-function manual hospital bed with backrest adjustment to 70±10° and knee-rest adjustment to 30±10°, a fixed bed height of 500 mm, 200 kg safe working load and external dimensions of 2150 × 960 × 500 mm. Manufactured by Keling Medical (Keling Medical) for general wards and care facilities that require manual patient positioning without height adjustment or electric drive systems.

Model
KL-BC107
Category
Hospital Beds
Supplier
Keling Medical
Order type
B2B, distributor and project inquiry
  • The Keling KL-BC107 is a 2-function manual hospital bed with crank-operated backrest and knee-rest adjustment.
  • Backrest adjusts manually to 70±10° for respiratory, feeding and comfort positions.
  • Knee-rest adjusts independently to 30±10°, reducing patient sliding when the backrest is raised.
  • Bed height is fixed at 500 mm; external size is 2150 × 960 × 500 mm; bed surface is 1930 × 900 mm.
CertificatesConfirm by model
MOQConfirm by quote
Lead timeConfirm by order
CustomizationFeasibility review

Include quantity, destination, voltage, accessories, required certificates and delivery target.

# KL-BC107 Manual Hospital Bed — 2-Function Bed with Backrest and Knee-Rest Adjustment

Quick answer: The Keling KL-BC107 is a 2-function manual hospital bed with backrest adjustment to 70±10° and knee-rest adjustment to 30±10°, a fixed bed height of 500 mm, 200 kg safe working load and external dimensions of 2150 × 960 × 500 mm. Manufactured by Keling Medical (Keling Medical) for general wards and care facilities that require manual patient positioning without height adjustment or electric drive systems.

Quick Facts

  • The Keling KL-BC107 is a 2-function manual hospital bed with crank-operated backrest and knee-rest adjustment.
  • Backrest adjusts manually to 70±10° for respiratory, feeding and comfort positions.
  • Knee-rest adjusts independently to 30±10°, reducing patient sliding when the backrest is raised.
  • Bed height is fixed at 500 mm; external size is 2150 × 960 × 500 mm; bed surface is 1930 × 900 mm.
  • Safe working load is 200 kg, rated for standard adult inpatient populations.
  • The KL-BC107 is manufactured by Keling Medical, a Chinese medical equipment producer with more than 20 years of industry experience.

Overview

The KL-BC107 manual hospital bed extends the single backrest function of the KL-BC106 by adding independent manual knee-rest adjustment, giving nursing staff the two most clinically relevant positioning controls in a low-maintenance, manually operated platform. The combination of backrest and knee-rest adjustment enables effective anti-sliding positioning that keeps patients comfortably seated in the bed during elevated postures without the need for repositioning every few hours.

The 70±10° backrest range covers the standard clinical requirements for head-of-bed elevation in respiratory care, post-operative recovery and feeding protocols. The 30±10° knee-rest angle, operated independently, provides the lower-limb support that counteracts the tendency for patients to slide toward the foot of the bed when the head is raised — reducing shear stress on the sacral and heel regions and contributing to pressure-injury prevention in long-stay patients.

With a fixed height of 500 mm and a compact 960 mm external width, the KL-BC107 is dimensionally identical to the KL-BC106, allowing the two models to be used interchangeably within the same ward layout. Manual operation keeps servicing requirements low: no electric motor, control box or wiring to maintain. The 200 kg load rating and 1930 × 900 mm bed surface ensure the KL-BC107 accommodates the full range of standard adult inpatients.

Key Features

  • 2-Function manual adjustment — independent crank-operated backrest and knee-rest adjustment.
  • Backrest to 70±10° — manual elevation covering full clinical positioning range from flat to near-upright.
  • Knee-rest to 30±10° — independent knee elevation reduces patient sliding and sacral pressure.
  • Fixed height 500 mm — consistent stable working height for standard ward environments.
  • 200 kg safe working load — rated for standard adult inpatient use.
  • Compact 960 mm external width — space-efficient footprint matching standard ward bay dimensions.
  • No electric components — manual operation for low maintenance requirements.

Technical Specifications

ParameterValue
ModelKL-BC107
Product typeManual hospital bed (2-function)
Backrest adjustment70±10°
Knee-rest adjustment30±10°
Bed height (fixed)500 mm
Safe working load200 kg
External size (L × W × H)2150 × 960 × 500 mm
Bed surface size (L × W)1930 × 900 mm
Dimensional tolerance±20 mm

Specifications are subject to change; dimensional tolerances may apply. Contact Keling Medical for the latest datasheet.

Applications

The KL-BC107 is suited to general medical and surgical wards, long-term care facilities, nursing homes, community hospitals and outpatient observation settings. The two-function manual configuration is appropriate for post-acute and lower-acuity inpatient environments where backrest and knee-rest positioning meet the day-to-day clinical needs without requiring electric systems or height adjustment.

Product questions

Frequently Asked Questions

Answers for initial model evaluation. Commercial terms, certificates and final configuration remain subject to written confirmation.

What is the Keling KL-BC107 manual hospital bed used for?

The KL-BC107 is a 2-function manual hospital bed for general ward and long-term inpatient care. It provides manual backrest and knee-rest adjustment, enabling nursing staff to maintain comfortable anti-sliding patient positioning and head-of-bed elevation for respiratory care, feeding and therapeutic positioning.

How does the KL-BC107 differ from the KL-BC106?

Both the KL-BC106 and KL-BC107 are 1- and 2-function manual beds, respectively, with the same 200 kg load, 500 mm fixed height and 2150 × 960 mm external dimensions. The KL-BC107 adds independent manual knee-rest adjustment (30±10°) compared to the KL-BC106's backrest-only function, providing better anti-sliding positioning when the backrest is elevated.

Does the KL-BC107 have electric controls?

No. The KL-BC107 is a fully manual bed. Backrest and knee-rest positions are set using manual cranks, eliminating the need for electric power or electronic control systems. For electric backrest and knee-rest adjustment, Keling Medical offers the KL-BC105 (2-function electric) or KL-BC104 (3-function electric) models.

Can the KL-BC107 be sourced in volume for hospital procurement?

Yes. Keling Medical is an export-oriented manufacturer supplying hospitals and distributors worldwide and handles bulk and project-volume orders through its Shanghai export center. Contact Keling Medical at https://www.kelingmed.com for quotations and product specifications.

B2B procurement information

Items to confirm for KL-BC107

A product page supports initial selection. The following commercial and compliance details must be confirmed for the actual destination and order.

Product configuration

Functions, dimensions, accessories, voltage, plug, language, color and optional components.

Compliance documents

Current certificate scope, declaration, datasheet and destination-market document needs.

Commercial terms

Unit price, MOQ, lead time, Incoterm, payment, warranty and spare-parts arrangement.

Packing information

Package type, quantity per package, dimensions, gross weight and shipping marks.

Project coordination

Equipment schedule, model alternatives, required delivery milestone and document submission plan.

Order confirmation

Final specifications and documents should be attached to the formal quotation or contract.

Important: Website specifications may be updated. Use the latest signed quotation, datasheet and approved configuration as the purchasing reference.

Model-specific RFQ

Request a commercial and document review

To reduce back-and-forth, include the following information:

  • Model: KL-BC107
  • Required quantity and purchasing frequency
  • Destination country and preferred Incoterm
  • Voltage, plug, language and accessories
  • Required certificates or tender documents
  • Target delivery date and packaging marks

Do not send patient information or other sensitive medical data.

Send your requirements

If no external form service is configured, your email application will open with the inquiry details. Do not submit patient data or sensitive personal information.

B2B project inquiry

Planning a medical equipment project?

Share your BOQ, quantities, destination, delivery target and required documents.

Discuss Your Requirements →